Electric Know HowLearn with Electric Know HowExplore the library
Switchgear

Busbar-Types of Busbar and ground clearances

Tubular conductors on supports

This electrical Busbar training course introduces basic safe operational and field diagnostics of busbars with a focus on safe operation, testing, and maintenance of normally installed in substations.

What is busbar in substation?

  • Busbar is a system where all incoming and outgoing feeders, lines, and transformers are connected through an isolator and breaker.
  • The selection of any busbar system depends upon
    • Amount of flexibility required in operation.
    • Immunity from the total shutdown.
    • The initial cost of the installation.
    • Load handled by the busbar.

Different Configurations of bus-bar system

  • Single busbar
  • Main and Transfer Bus
  • Double Busbar.
  • Ring mains system

SINGLE BUS-BAR

Electrical engineering illustration
Single Busbar
  • Main and Transfer Bus

With this arrangement, all the feeders are normally on the Main Bus Bar. If at any time, a Line Circuit  Breaker/ Transformer circuit breaker Maintenance is required or breakdown of a Circuit breaker or CTs, that particular feeder/ transformer, can be transferred onto the Transfer Bus. The feeder protection thus gets transferred to the trip Transfer Bus Coupler Breaker. On fault occurrence or maintenance, the entire bus becomes de-energized.

Electrical engineering illustration
Main and Transfer Bus

Two main or Double Bus

There are five types of Bus switching schemes double bus bars

  • Double busbar system.
  • Double bus with sectionaliser system.
  • Double bus & transfer bus system.
  • Double bus & transfer bus with sectionaliser system.
  • One & half breaker system
Electrical engineering illustration
Two main busbar system

Ring Main Bus System

The schematic diagram of the system is given in the figure. It provides a double feed to each feeder circuit, opening one breaker under maintenance or otherwise does not affect the supply to any feeder.

major disadvantage

One as it is a closed circuit system it is next to impossible to extend in the future and hence it is unsuitable for developing systems.

Electrical engineering illustration

Types of Bus Bar

  • Rigid Bus In the rigid type, pipes are used for bus bars and also for making connections among various equipment wherever required.Since the bus bars are rigid the clearances remain constant.Due to the large diameter of the pipes, the corona loss is also substantially less.

strain type bus bars

The strain-type bus bars are an overhead system of wires strung between two supporting structures and supported by strain-type insulators.

The stringing tension may be limited to 500-900 kg depending upon the size of the conductor used. These types of busbars are suitable for earthquake-prone areas.

Electrical safety clearances

The various clearances need to be defined.

  • Phase-to-earth clearance.
  • Phase-to-phase clearance.
  • Sectional clearance.
  • Ground clearance.
  • Equipment to equipment spacing
Electrical engineering illustration

For more Questions and Answer